Demonstration from 1965 of interruption of fistula and insertion of graft in pediatric patient with single coronary artery wrapping around the heart. Graft is a Dacron tube graft. Film has voice over narration by Don Macon and illustrations by Herb Smith and Robin Hanson.
Demonstration dated 03/10/1979 of transplantation of the human heart. A plastic bubble oxygenator is used. Film has voice over narration by Don Macon and illustrations by Barry Baker.
Demonstration from 1965 of interruption of fistula and insertion of graft in pediatric patient with single coronary artery wrapping around the heart. Graft is a Dacron tube graft. Film has voice over narration by Don Macon and illustrations by Herb Smith and Robin Hanson.
Demonstration dated 07/07/1979 of excision of false aneurysm using cardiopulmonary bypass. A plastic bubble oxygenator is used. Film has voice over narration and illustrations by Herb Smith.
Demonstration dated 04/17/1969 of transplantation of the human heart. A plastic bubble oxygenator is used. Film has voice over narration by Lucien Stervinou and illustrations by Barry Baker.
Demonstration from 1966 of two pediatric surgeries to correct anomalous coronary artery arising from pulmonary artery. Vein grafts and Dacron grafts are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration circa 1966 of septectomy to treat muscular subaortic stenosis in two patients. Pump oxygenators are used. Film has voice over narration by Don Macon and illustrations by Barry Baker and Herb Smith.
Demonstration from 1970 of surgery to correct cor triatriatum in a pediatric patient. Diaphragm is excised using cardiopulmonary bypass. Film has voice over narration by Don Macon and illustrations by Herb Smith and Robin Hanson.
Demonstration circa 1966 of surgery to excise thoraco-abdominal aneurysm where visceral arteries are anastomosed directly to the main aortic graft. A pump oxygenator and Dacron tube graft are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration circa 1966 of surgery to excise thoraco-abdominal aneurysm where visceral arteries are anastomosed directly to the main aortic graft. A pump oxygenator and Dacron tube graft are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration circa 1966 of septectomy to treat muscular subaortic stenosis in two patients. Pump oxygenators are used. Film has voice over narration by Don Macon and illustrations by Barry Baker and Herb Smith.
Demonstration from 1967 of surgery to excise thoraco-abdominal aneurysm where visceral arteries are anastomosed directly to the main aortic graft. A pump oxygenator and Dacron tube graft are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration from 1966 of two pediatric surgeries to correct anomalous coronary artery arising from pulmonary artery. Vein grafts and Dacron grafts are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration from 1967 of surgery to correct cor triatriatum in a pediatric patient. Diaphragm is excised using cardiopulmonary bypass. Film has voice over narration by Don Macon and illustrations by Herb Smith and Robin Hanson.
Demonstration circa 1968 of excision of cyst of left ventricle attached to mitral valve. A bubble oxygenator is used. Film has voice over by Don Macon and illustrations by Herb Smith.
Demonstration from 1970 of surgery to correct cor triatriatum in a pediatric patient. Diaphragm is excised using cardiopulmonary bypass. Film has voice over narration by Don Macon and illustrations by Herb Smith and Robin Hanson.
Demonstration from 1968 of Cooley-Liotta-Cromie prosthesis for aortic valve and surgical replacement of the aortic valve with the prosthesis. Prosthesis is a titanium ball in Dacron velour covered prosthesis for aortic valve replacement. The film has voice over narration by Don Macon and illustrations.
Demonstration circa 1966 of replacement of cardiac valves using the SCDK-Cutter double caged valve prosthesis. Surgeries use disposable bubble oxygenators and replace mitral or aortic valves. Statistics on surgeries for 250 patients are provided. The film has voice over narration by Don Macon and illustrations by Herb Smith, Kathleen Norris, and Robin Hanson.
Demonstration from 1966 of two pediatric surgeries to correct anomalous coronary artery arising from pulmonary artery. Vein grafts and Dacron grafts are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration circa 1974 of surgical management of tetralogy of fallot in multiple pediatric patients. Palliative surgeries as well as later, total correction are demonstrated. A disposable bubble oxygenator is used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Robin Hanson, Paulette Wells, and Herb Smith.
Demonstration circa 1969 through multiple surgeries of treatment of ventricular septal defect in infants. A constricting band is placed around the main artery in infancy and further surgery is done to correct the defect and remove the band when the patient is older. Film has voice over by Don Macon and illustrations.
Demonstration circa 1966 through multiple surgeries of treatment for children born with aorta and pulmonary artery transposed. Using techniques developed by Blalock and Hamlin, palliative surgery is done in infancy with full correction done when the patient is older using the Mustard procedure. A pump oxygenator is used in the later surgery. Film has voice over by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration circa 1968 of surgical treatment of left ventricular aneurysm, along with dissection of post-mortem heart. A disposable bubble oxygenator and Dacron sutures are used. Some statistical analysis of patient outcomes follows the demonstration. Film has voice over narration by Don Macon and illustrations by Herb Smith.
Demonstration circa 1966 of surgical replacement of aortic valve and aortic arch. A Dacron patch and Smeloff-Cutter valve prosthesis are implanted and a disposable bubble oxygenator is used. The film also summarizes surgical techniques, prostheses, and patient outcomes for similar surgeries. Film has voice over narration by Don Macon and illustrations by Herb Smith, Kathleen Norris, and Robin Hanson.
Demonstration circa 1968 of insertion of prosthesis to replace mitral valve in seven year old patient. A disposable bubble oxygenator is used. Statistics are included on the hospital's treatment of children with mitral valve stenosis. Film has voice over narration by Don Macon and illustrations by Barry Baker.
Demonstration dated 04/27/1979 of repair of traumatic rupture of thoracic aorta. A pump oxygenator is used and a Dacron graft inserted. Film has voice over by Don Macon and illustrations by George Batik.
Demonstration from 1969 of surgery to correct right pulmonary artery originating from ascending aorta in a newborn. A Dacron tube graft is used. Film has voice over narration by Don Macon and illustrations by Mario de Leon.
Demonstration dated 07/07/1979 of palliative surgery in infants with congenital heart disease. Because full surgical correction with cardiopulmonary bypass is too risky for infants, palliative surgery is performed. Conditions and treatments discussed include tricupid artresia potts anastomosis, transposition of the great vessels and creation of atrial septal defect, patent ductus arteriosis suture ligation, coarctation resection and anastomosis, congenital aortic vacsular ring division of couble aortic arch, ventricular septal defect pulmonary artery banding, and aortic stenosis valvotomy with modified caval occlusion. Statistics on patients and outcomes are included. Film has voice over narration by Don Macon.
Demonstration circa 1966 of surgery to excise thoraco-abdominal aneurysm where visceral arteries are anastomosed directly to the main aortic graft. A pump oxygenator and Dacron tube graft are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.