Demonstration from 1965 of interruption of fistula and insertion of graft in pediatric patient with single coronary artery wrapping around the heart. Graft is a Dacron tube graft. Film has voice over narration by Don Macon and illustrations by Herb Smith and Robin Hanson.
Demonstration from 1965 of interruption of fistula and insertion of graft in pediatric patient with single coronary artery wrapping around the heart. Graft is a Dacron tube graft. Film has voice over narration by Don Macon and illustrations by Herb Smith and Robin Hanson.
Demonstration from 1966 of two pediatric surgeries to correct anomalous coronary artery arising from pulmonary artery. Vein grafts and Dacron grafts are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration circa 1966 of surgery to excise thoraco-abdominal aneurysm where visceral arteries are anastomosed directly to the main aortic graft. A pump oxygenator and Dacron tube graft are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration circa 1966 of surgery to excise thoraco-abdominal aneurysm where visceral arteries are anastomosed directly to the main aortic graft. A pump oxygenator and Dacron tube graft are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration circa 1975 of aneurysm resection and graft replacement. A Dacron graft and pump oxygenator are used. Film has illustrations by Barbara E. Hyams.
Demonstration from 1967 of surgery to excise thoraco-abdominal aneurysm where visceral arteries are anastomosed directly to the main aortic graft. A pump oxygenator and Dacron tube graft are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration from 1966 of two pediatric surgeries to correct anomalous coronary artery arising from pulmonary artery. Vein grafts and Dacron grafts are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration circa 1978 of aneurysm resection and graft replacement. A Dacron graft and pump oxygenator are used. Film has voice over and illustrations by Barbara E. Hyams.
Summary from 1961 of techniques used in surgical treatment of ventricular septal defects, including demonstration of pediatric surgery. Two treatment techniques are demonstrated: suture and Dacron patch graft prothesis. A pump oxygenator is used. Film has voice over by Don Macon and illustrations by Barbara Tuttle.
Demonstration from 1968 of Cooley-Liotta-Cromie prosthesis for aortic valve and surgical replacement of the aortic valve with the prosthesis. Prosthesis is a titanium ball in Dacron velour covered prosthesis for aortic valve replacement. The film has voice over narration by Don Macon and illustrations.
Discussion and demonstration from 1963 of surgical treatments for atrial septal defects. For a pediatric patient, sutures are used
for one adult and one child, Dacron patch grafts are implanted. Both surgeries use pump oxygenators. The film has voice over narration by Don Macon and illustrations by Barbara Tuttle.
Discussion and demonstration from 1963 of surgical treatments for atrial septal defects. For a pediatric patient, sutures are used
for one adult and one child, Dacron patch grafts are implanted. Both surgeries use pump oxygenators. The film has voice over narration by Don Macon and illustrations by Barbara Tuttle.
Demonstration from 1966 of two pediatric surgeries to correct anomalous coronary artery arising from pulmonary artery. Vein grafts and Dacron grafts are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration from 1973 of surgery to correct ventricular septal defect using a polyester Dacron cloth patch. A pump oxygenator with Cooley Sherwood bag is used. Film has voice over by Don Macon and illustrations.
Demonstration circa 1974 of surgical management of tetralogy of fallot in multiple pediatric patients. Palliative surgeries as well as later, total correction are demonstrated. A disposable bubble oxygenator is used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Robin Hanson, Paulette Wells, and Herb Smith.
Demonstration circa 1968 of surgical treatment of left ventricular aneurysm, along with dissection of post-mortem heart. A disposable bubble oxygenator and Dacron sutures are used. Some statistical analysis of patient outcomes follows the demonstration. Film has voice over narration by Don Macon and illustrations by Herb Smith.
Demonstration circa 1966 of surgical replacement of aortic valve and aortic arch. A Dacron patch and Smeloff-Cutter valve prosthesis are implanted and a disposable bubble oxygenator is used. The film also summarizes surgical techniques, prostheses, and patient outcomes for similar surgeries. Film has voice over narration by Don Macon and illustrations by Herb Smith, Kathleen Norris, and Robin Hanson.
Demonstration circa 1968 of insertion of prosthesis to replace mitral valve in seven year old patient. A disposable bubble oxygenator is used. Statistics are included on the hospital's treatment of children with mitral valve stenosis. Film has voice over narration by Don Macon and illustrations by Barry Baker.
Demonstration circa 1980 of repair of aneurysm transverse aortic arch. A pump oxygenator is used to induce hypothermia and a Dacron tube graft is inserted. Film has voice over by Don Macon and illustrations by Bill Andrews.
Demonstration dated 04/27/1979 of repair of traumatic rupture of thoracic aorta. A pump oxygenator is used and a Dacron graft inserted. Film has voice over by Don Macon and illustrations by George Batik.
Demonstration from 1969 of surgery to correct right pulmonary artery originating from ascending aorta in a newborn. A Dacron tube graft is used. Film has voice over narration by Don Macon and illustrations by Mario de Leon.
Discussion circa 1976 of uses for Cooley-Meadox double velour grafts with demonstration of use to replace major arteries. Steps to prepare and surgically implant graft are shown with three patients. Film has voice over narration by Don Macon and illustrations by Barbara E. Hyams.
Demonstration from 4/7/1969 of cardiac replacement in two stages. First, after a failed attempt at surgical repair of the heart, a Liotta-Cooley artificial heart, Dacron tubes, and a Wada-Cutter hingeless valve prosthesis are implanted as a palliative measure. A donated heart is transplanted in a later surgery. A disposable bubble oxygenator is used. Film has voice over narration by Don Macon and illustrations.
Demonstration circa 1978 of apico-aortic bypass for left ventricular outflow obstructions. A Bjork-Shiley prosthesis and disposable pump oxygenator are used. Film has voice over narration by Don Macon and illustrations by Timothy Hengst.
Demonstration circa 1966 of surgery to excise thoraco-abdominal aneurysm where visceral arteries are anastomosed directly to the main aortic graft. A pump oxygenator and Dacron tube graft are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration of technique to treat high risk patients needing coronary artery bypass. Preoperative balloon support with Dacron graft and topical hypothermia are used. Film has voice over by Don Macon and illustrations.