- AVF.IC043.060
- Item
- circa 1975
Demonstration circa 1975 of aneurysm resection and graft replacement. A Dacron graft and pump oxygenator are used. Film has illustrations by Barbara E. Hyams.
21 results directly related Exclude narrower terms
Demonstration circa 1975 of aneurysm resection and graft replacement. A Dacron graft and pump oxygenator are used. Film has illustrations by Barbara E. Hyams.
Demonstration circa 1978 of aneurysm resection and graft replacement. A Dacron graft and pump oxygenator are used. Film has voice over and illustrations by Barbara E. Hyams.
Apico-Aortic Bypass For Left Ventricular Outflow Obstructions Using Composite Conduits
Demonstration circa 1978 of apico-aortic bypass for left ventricular outflow obstructions. A Bjork-Shiley prosthesis and disposable pump oxygenator are used. Film has voice over narration by Don Macon and illustrations by Timothy Hengst.
Cardiac Valve Replacement Using An Improved Prosthesis
Demonstration circa 1966 of replacement of cardiac valves using the SCDK-Cutter double caged valve prosthesis. Surgeries use disposable bubble oxygenators and replace mitral or aortic valves. Statistics on surgeries for 250 patients are provided. The film has voice over narration by Don Macon and illustrations by Herb Smith, Kathleen Norris, and Robin Hanson.
Combined Mitral and Aortic Valve Replacement Using Improved Prostheses
Demonstration circa 1974 of Cooley-Cutter prostheses for mitral and aortic valves and surgical replacement of the mitral and aortic valves with the protheses. The low-profile prosthesis has a Pyrolite carbon poppet in a double-cage titanium frame. Film has voice over narration and illustrations.
Cooley-Meadox Double Velour Grafts in Vascular Surgery
Discussion circa 1976 of uses for Cooley-Meadox double velour grafts with demonstration of use to replace major arteries. Steps to prepare and surgically implant graft are shown with three patients. Film has voice over narration by Don Macon and illustrations by Barbara E. Hyams.
Correction of Anomalous Coronary Artery Arising From Pulmonary Artery
Demonstration from 1966 of two pediatric surgeries to correct anomalous coronary artery arising from pulmonary artery. Vein grafts and Dacron grafts are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Correction of Anomalous Coronary Artery Arising From Pulmonary Artery
Demonstration from 1966 of two pediatric surgeries to correct anomalous coronary artery arising from pulmonary artery. Vein grafts and Dacron grafts are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Correction of Anomalous Coronary Artery Arising From Pulmonary Artery
Demonstration from 1966 of two pediatric surgeries to correct anomalous coronary artery arising from pulmonary artery. Vein grafts and Dacron grafts are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Medtronic Model 4951 Permanent Lead: “A New Alternative in Epicardial Pacing”
Promotional video from 1982 for Medtronic epicardial leads. Demonstrates implantation of Medtronic pacemaker in two patients, including one pediatric patient. Film has voice over and illustrations.
Mitral Valve Replacement In Childhood
Demonstration circa 1968 of insertion of prosthesis to replace mitral valve in seven year old patient. A disposable bubble oxygenator is used. Statistics are included on the hospital's treatment of children with mitral valve stenosis. Film has voice over narration by Don Macon and illustrations by Barry Baker.
Prosthesis for Aortic Valve Replacement
Demonstration from 1968 of Cooley-Liotta-Cromie prosthesis for aortic valve and surgical replacement of the aortic valve with the prosthesis. Prosthesis is a titanium ball in Dacron velour covered prosthesis for aortic valve replacement. The film has voice over narration by Don Macon and illustrations.
Simplified Technic for Excision of Thoraco-Abdominal Aneurysm
Demonstration circa 1966 of surgery to excise thoraco-abdominal aneurysm where visceral arteries are anastomosed directly to the main aortic graft. A pump oxygenator and Dacron tube graft are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Simplified Technic for Excision of Thoraco-Abdominal Aneurysm
Demonstration circa 1966 of surgery to excise thoraco-abdominal aneurysm where visceral arteries are anastomosed directly to the main aortic graft. A pump oxygenator and Dacron tube graft are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Simplified Technic for Excision of Thoraco-Abdominal Aneurysm
Demonstration from 1967 of surgery to excise thoraco-abdominal aneurysm where visceral arteries are anastomosed directly to the main aortic graft. A pump oxygenator and Dacron tube graft are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Simplified Technic for Excision of Thoraco-Abdominal Aneurysm
Demonstration circa 1966 of surgery to excise thoraco-abdominal aneurysm where visceral arteries are anastomosed directly to the main aortic graft. A pump oxygenator and Dacron tube graft are used. Film has voice over narration by Don Macon and illustrations by Barry Baker, Herb Smith, and Paulette Wells.
Demonstration from 1965 of interruption of fistula and insertion of graft in pediatric patient with single coronary artery wrapping around the heart. Graft is a Dacron tube graft. Film has voice over narration by Don Macon and illustrations by Herb Smith and Robin Hanson.
Demonstration from 1965 of interruption of fistula and insertion of graft in pediatric patient with single coronary artery wrapping around the heart. Graft is a Dacron tube graft. Film has voice over narration by Don Macon and illustrations by Herb Smith and Robin Hanson.
Demonstration from 4/7/1969 of cardiac replacement in two stages. First, after a failed attempt at surgical repair of the heart, a Liotta-Cooley artificial heart, Dacron tubes, and a Wada-Cutter hingeless valve prosthesis are implanted as a palliative measure. A donated heart is transplanted in a later surgery. A disposable bubble oxygenator is used. Film has voice over narration by Don Macon and illustrations.
Surgical Treatment of Atrial Septal Defects: An Analysis of 360 Cases
Surgical Treatment of Ventricular Septal Defects: Technique & Results in 292 Cases
Summary from 1961 of techniques used in surgical treatment of ventricular septal defects, including demonstration of pediatric surgery. Two treatment techniques are demonstrated: suture and Dacron patch graft prothesis. A pump oxygenator is used. Film has voice over by Don Macon and illustrations by Barbara Tuttle.